Protect Rytons cavity weep hole ducts and ventilators from the entry of dust, debris and render during construction with Rytons DamRyt range of temporary site protection units. Rytons DAMWEEP protects the weep outlet of Rytons Rytweep® while Rytons DAMSLIMVENT protects the vent/weep opening of Rytons Slim Vent® Minor SVMIN and Flyscreened Slim Vent® Minor SVFMIN. [...]
Did you know Rytons invented the first pre-formed perpend cavity vent over 50 years ago? In 1972 Rytons launched the Slim Vent® Minor, giving architects and contractors a new quick, easy and uniform way of preventing condensation in cavity walls. It was so simple and effective that pre-formed units soon became the industry standard they [...]
Outlining the Regulations The Building (Scotland) Regulations - Domestic Cavities should be vented to the outside air by installing ventilators with at least 300mm² free opening area at 1.2m maximum centres. Precipitation can penetrate the outer leaf of an external wall and cavities are normally drained through weep holes. These weep holes can also provide [...]