Rytons A1 Fire-rated 9×3 AirLiner® with Single Air Brick Grille

General Details

Rytons A1 Fire-rated 9×3 AirLiner® with Single Air Brick Grille

  • A custom-made galvanised steel AirLiner® cross-cavity ventilator.
  • Choose from three styles of air brick to achieve the design, air flow and positioning requirements of the development.
  • Air brick supplied in an extensive choice of RAL colours (achieving A2-s1, d0), to complement the façade and maintain the external appearance of the building.
  • New, improved air brick features discreet precautionary drainage holes, providing an outlet for any water ingress to prevent transfer into the ducting.
  • Custom sizing and bespoke design service available.
  • Suitable for use in high-rise buildings with a storey 18m or more above ground level to Regulation 7(2) and Building Regulations Approved Document B.
  • Suitable for use in buildings with a storey 11m or more above ground level to Building (Scotland) technical handbook 2019: domestic and non-domestic, 2.7.
  • Product considered fire class A1 without testing, as per European Commission paper 96/603/EC referred to in BS EN 13501-1:2018.
  • Material not compromised at a temperature of 800°C, as required by the Building Regulations Approved Document B for ductwork spanning the cavity.
  • Classification: A1.  Definition: Non-combustible.  Description: No contribution to fire.

Rytons A1 Fire-rated 9×3 AirLiner® with Single Return Grilles:

Rytons A1 Fire-rated 9×3 AirLiner® with Single Return Grille
Single Return Grille Air Brick. 7,200mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087696. Product Code: A1AL93RGS.

Rytons A1 Fire-rated 9×3 AirLiner® with Single Return Grille Flanged
Single Return Grille Air Brick with 15mm flange and corner screw holes. 7,200mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087697. Product Code: A1AL93RGSF.

Rytons A1 Fire-rated 9×3 AirLiner® with Single Square Holed Grilles:

Rytons A1 Fire-rated 9×3 AirLiner® with Single Square Holed Grille
Single Square Holed Air Brick. 9,032mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087696. Product Code: A1AL93SQS.

Rytons A1 Fire-rated 9×3 AirLiner® with Single Square Holed Grille Flanged
Single Square Holed Air Brick with 15mm flange and corner screw holes. 9,032mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087697. Product Code: A1AL93SQSF.

Rytons A1 Fire-rated 9×3 AirLiner® with Single FlowRyt® Grilles:

Rytons A1 Fire-rated 9×3 AirLiner® with Single FlowRyt® Grille
Single FlowRyt® Air Brick. 8,000mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087696. Product Code: A1AL93FRS.

Rytons A1 Fire-rated 9×3 AirLiner® with Single FlowRyt® Grille Flanged
Single FlowRyt® Air Brick with 15mm flange and corner screw holes. 8,000mm² free area.
Custom RAL colour grille in matt, semi-gloss or gloss finish (achieving A2-s1, d0).
Custom length. Note: Rytons recommend 100mm in addition to the measurement from the outer leaf to the inner leaf.
Properties: A1 fire-rated 0.9mm galvanised steel. Fire-rated RAL colour powder coating (achieving a test result of A2-s1, d0). Spot welded. Ever Build intumescent fire protection and acoustic sealant (product code FIREMATE) used on all gaps.
Registered Design 6087697. Product Code: A1AL93FRSF.

NBS Specifications:

Regulations/Reference Material:

  • The Building Regulations Approved Document B (Fire safety) – Volume 1: Dwellings (2019 edition). Appendix B: Performance of materials, products and structures B4. NOTE: Regulation 7(2) limits components used in or on the external walls of certain buildings to materials achieving class A2-s1, d0 or class A1 (see Section 10). Assessments cannot be used to demonstrate compliance with this requirement.
  • The Building Regulations Approved Document B (Fire safety) – Volume 2: Buildings other than dwellings (2019 edition). Appendix B: Performance of materials, products and structures B4. NOTE: Regulation 7(2) limits components used in or on the external walls of certain buildings to materials achieving class A2-s1, d0 or class A1 (see Section 10). Assessments cannot be used to demonstrate compliance with this requirement.
  • Building (Scotland) technical handbook 2019: domestic. 2.7 Spread on external walls. 2.7.1 External wall cladding. Storey height more than 11m – Where the building has a storey at a height of more than 11m above the ground the external wall cladding system should be constructed of products achieving European Classification A1 or A2.

  • Building (Scotland) technical handbook 2019: non-domestic. 2.7 Spread on external walls. 2.7.2 Specified attachments. There is a risk of vertical fire spread from specified attachments to an external wall including balconies, solar panels and solar shading. Solar shading are devices attached to an external wall to reduce heat gain within a building by deflecting sunlight. Fire-fighters may not be able to apply a water jet from a fire-fighting hose directly onto a fire that has spread onto specified attachments high above the ground.
  • Where the building has a storey at a height of more than 11m above the ground, specified attachments should be constructed of products achieving European Classification A1 or A2.
  • Extracts from NHBC Technical Extra 25.
  • Page 14: Note: in most cases, a panel of the tested system wouldn’t contain all the components necessary to function as an external wall (for example, cavity trays, weep holes, etc.). Therefore, any additional components must achieve Class A1or A2-s1, d0.
  • Page 16: Minor components within or passing through an external wall: The aim of the regulation is to remove all combustible components from, or within, an external wall.  The majority of air bricks, weep holes, ventilation ducts, etc. can be produced from materials meeting Class A1 or A2-s1, d0, so products meeting these classifications should be used.
Pressure Loss Data